Once again making waves in the power tool industry, Dewalt's new line of 12v MAX power tools has been making a real ruckus since its debut in early October of 2010. The thermometer additionally features adjustable emissivity for improved accuracy throughout a range of different materials, and with data storage as well, the thermometer easily records the minimum, maximum, and average temperatures of your workspace.
While some have argued even a ±0.5°C difference could negatively influence clinical decision making, many veterinary thermometers have an inherent accuracy non contact infrared thermometer of ±0.2°C and different operators and techniques for measuring RT have been shown to differ by up to 0.5°C in the same animal (Naylor et al, 2012).

The design essentially consists of a lens to focus the infrared thermal radiation on to a detector , which converts the radiant power to an electrical signal that can be displayed in units of temperature after being compensated for ambient temperature.
When the temperature of a surface is accurately known (e.g. by measuring with a contact thermometer), then the sensor's emissivity setting can be adjusted until the temperature measurement by the IR method matches the measured temperature by the contact method; the emissivity setting will indicate the emissivity of the surface, which can be taken into account for later measurements of similar surfaces (only).

This Temple thermometer has been clinically tested in several big teaching hospitals based on the protocol of ASTM E1965-98:2009 regulatory standard, covering sufficient febrile and normal body temperature subjects with satisfied clinical repeatability and measuring accuracy comparing to the concurrent oral temperature measurement reading.
NCIT measurements were executed in the mid-forehead following the manufacturer's instructions (Thermofocus, model 0800; Tecnimed, Varese, Italy) and according to the American Society for Testing and Materials (ASTM 2009) E 1965-1968 standard specifications for infrared thermometers for intermittent determination of patient temperature.
So, what happens is, when you get the Laser Thermometer with Infrared closer to subject or object intended to be measured the mirrors or lenses present in the subject or object is focused by the detector, this detector then converts this infrared energy into the electrical signals and then into units of the temperature without being physically in touch with the subject or object.